Minimum since 2023
- Split AC, under 45,000 Btu/h
- 14.3 SEER2
- Split AC, 45,000 Btu/h and up
- 13.8 SEER2
- Split heat pump
- 14.3 SEER2 · 7.5 HSPF2
- Single-package AC
- 13.4 SEER2
- Single-package heat pump
- 13.4 SEER2 · 6.7 HSPF2
Guide · Efficiency
What SEER2, EER2 and HSPF2 measure, the minimum ratings for new systems in Florida, and how to read the numbers on a quote or a data plate.

SEER2 tells you how efficiently an air conditioner or heat pump cools over a whole season. EER2 tells you how efficiently it cools at full load on a 95°F afternoon. HSPF2 rates a heat pump's heating. Since 2023, every new central system is rated on these "2" versions. They come from a tougher test than the old SEER, EER and HSPF, so the numbers read lower for similar equipment. In Florida, a split-system AC smaller than 45,000 Btu/h must be at least 14.3 SEER2.
Higher numbers mean lower operating cost for the same cooling. But a rating is what the equipment can do under test conditions; how it's sized and installed decides what it actually does in your house.
For a Broward home, SEER2 is the number most connected to the electric bill, because the cooling season runs most of the year. EER2 is a useful second look at how a system handles the hottest part of the day. HSPF2 matters very little here, because heating hours are few.
On January 1, 2023, the U.S. Department of Energy switched to a new test procedure. One reason the new numbers are lower is that the test now assumes the system is pushing air through ductwork with more resistance, because DOE found that's closer to real homes. For conventional ducted systems the new test uses 0.50 inches of water column of external static pressure, compared with 0.10–0.20 under the old one.
DOE set the 2023 minimums in the old units first and then translated them. From those paired values, SEER2 runs roughly 4.5 to 5 percent lower than SEER for equivalent equipment, and HSPF2 about 15 to 16 percent lower than HSPF. That's our arithmetic from DOE's published levels, not an official conversion factor, and individual products vary. The practical rule: compare SEER2 with SEER2. A 2023-era 14.3 SEER2 minimum corresponds roughly to the old 15 SEER.
Federal minimums depend on where equipment is installed. Florida is in DOE's Southeast region, which has higher minimums for split-system air conditioners than the national level (the table below lists them). A few details are worth knowing:
Florida law and the state energy code tie in to these federal minimums: air conditioners sold or installed in Florida must meet them.
The SEER2 printed in a brochure is for a specific outdoor unit paired with a specific indoor coil or air handler, tested together. Pair the same outdoor unit with a different indoor coil and the rating changes, sometimes by a lot.
That's why Florida's energy code requires matched systems on replacements, and why a quote should name both halves of the system. If you're replacing a split system, ask for the rating of the exact combination being proposed. (See central air conditioners and heat pumps.)
A system only reaches its rated efficiency when it's sized, charged and installed correctly:
A higher-SEER2 system installed on leaky or undersized ductwork, or sized by copying the old unit, can easily perform worse than a lower-rated system installed well. The sizing guide explains why the size should come from a load calculation, and airflow and duct design covers the ductwork side.
Often, yes. A South Florida system runs so many hours a year that efficiency differences add up faster than they do in mild climates. But the decision is specific to the house and the budget. A sensible way to compare:
The plate above is an illustrative example of what to look for on a quote, not a recommendation for any particular home.
For the same cooling, seasonal electricity use falls as the SEER2 rating rises. Slide to compare against the minimum.
Federal minimums in effect since January 1, 2023. Florida is in DOE's Southeast region.
| Equipment | Minimum since 2023 | Roughly equivalent old rating |
|---|---|---|
| Split AC, under 45,000 Btu/h | 14.3 SEER2 | 15 SEER |
| Split AC, 45,000 Btu/h and up | 13.8 SEER2 | 14.5 SEER |
| Split heat pump | 14.3 SEER2 · 7.5 HSPF2 | 15 SEER · 8.8 HSPF |
| Single-package AC | 13.4 SEER2 | 14 SEER |
| Single-package heat pump | 13.4 SEER2 · 6.7 HSPF2 | 14 SEER · 8.0 HSPF |
Old-rating equivalents come from DOE's 2017 rule, which set the 2023 levels on the old test and then translated them; they're approximate. There is no EER2 minimum in the Southeast. 45,000 Btu/h is a little under 4 tons.
Example values are illustrative, not a recommendation for any particular house.
SEER2 numbers come from a tougher test, so they read roughly 4.5 to 5 percent lower than SEER for similar equipment, based on DOE's published equivalents. Today's Florida minimum for a smaller split system, 14.3 SEER2, corresponds roughly to the old 15 SEER. Compare SEER2 with SEER2 when you shop.
Not automatically. In South Florida, where a system runs most of the year, efficiency differences add up faster than in mild climates, so a higher rating often makes sense. But a higher-rated system that's oversized or installed on poor ductwork can perform worse than a lower-rated one installed well. Compare matched combinations of the right size, and make sure the installation details are in the quote.
We'll size the system to the house and show you the matched combinations and their ratings side by side.
The on-site evaluation for a new system is free.